Saudi plaster boards
Fire Rated Board (GKF)

Specifications:
This is the type of Boards which has fiber glass incorporated in its plaster core, thus achieving a greater Fire Resistance. Boards are manufactured according to German specification DIN 18180 and comply with ASTN C-36.

Edges: Tapered (T/E), Square (S/E), Beveled (B/E)
Thickness: 9.5mm, 12.5mm, 15mm, 18mm
Length: From 2000 to 4000mm (except 9.5mm : From 2000mm to 3660mm).

Nominal

Thickness

9.5mm

12.5mm

15mm

18mm

Board Weight (kg/m2)

DIN

8-10

10-13

13-16

14.4-18

Actual (mean)

8.8

11.5

13.7

18.0

Fire Rated Period

Passing

33 minutes

Passing

45 minutes

Passing

60 minutes

Passing

80 minutes

Breaking Load (N)

DIN

^

 

^

^

Min 450

Min 150

Min 600

Min 180

Min 600

Min 180

Min 600

Min 180

Actual (mean)

872

292

828

308

819

307

671

332

* ^ Perpendicular to Cardboard Fiber
* ║ Parallel to Cardboard fiber
* N Load in Newton

Fire Resistance Class: Din 4102 Class A2 (Non-Combustible)
Standard for safety: UL-263 for tests of building construction and materials.
- in case, require more fire resistance, this depends upon design and the erection systems.